EDS-405A-PN-T

Entry-level managed Ethernet switch with 5 10/100BaseT(X) ports, -40 to 75°C operating temperature, PROFINET enabled

Cantidad

Switch básico gestionable para Ethernet con 5 puertos 10/100BaseT(X), rango de temperatura de -40°C a 75°C, habilitado para PROFINET

Ficha de datos

10/100BaseT(X) Ports (RJ45 connector)
5 Auto negotiation speed Full/Half duplex mode Auto MDI/MDI-X connection
Industrial Protocols
EtherNet/IP Modbus TCP PROFINET
Management
Back Pressure Flow Control, BOOTP, DHCP Option 66/67/82, DHCP Server/Client, Flow control, IPv4/IPv6, LLDP, Port Mirror, RARP, RMON, SMTP, SNMP Inform, SNMPv1/v2c/v3, Syslog, Telnet, TFTP
MIB
Bridge MIB, Ethernet-like MIB, MIB-II, P-BRIDGE MIB, RMON MIB Groups 1, 2, 3, 9, RSTP MIB
Time Management
NTP Server/Client SNTP
Input Voltage
12/24/48 VDC, Redundant dual inputs
12/24/48 VDC, Redundant dual inputs
Dimensions
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
Peso
650 g (1.44 lb)
Installation
DIN-rail mounting, Wall mounting (with optional kit)
Housing
Metal
Metal
Operating Temperature
-40 to 75°C (-40 to 167°F)
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
Freefall
IEC 60068-2-31
EMC
EN 55032/24
Safety
UL 508 UL 60950-1
EMI
CISPR 32, FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF
Shock
IEC 60068-2-27
Vibration
IEC 60068-2-6
Time
1,547,941 hrs
Standards
Telcordia (Bellcore), GB
Warranty Period
5 years
Optical Fiber
-
Read More
MAC Table Size
2 K
Packet Buffer Size
1 Mbits
Connection
1 removable 6-contact terminal block(s)
1 removable 6-contact terminal block(s)
Input Current
0.21 A @ 24 VDC
0.21 A @ 24 VDC
Operating Voltage
9.6 to 60 VDC
9.6 to 60 VDC
Overload Current Protection
Supported
Supported
Reverse Polarity Protection
Supported
Supported
Ethernet Interface
Turbo Ring, Master, Coupler, Reserve
IP Rating
IP30
IP30
Hazardous Locations
ATEX Class I Division 2
Maritime
DNV-GL
Traffic Control
NEMA TS2
Details
See www.moxa.com/warranty
Filter
802.1Q VLAN, GMRP, GVRP, IGMP v1/v2, Port-based VLAN
Redundancy Protocols
RSTP, STP, Turbo Chain, Turbo Ring v1/v2
IGMP Groups
256
Max. No. of VLANs
64
Priority Queues
4
VLAN ID Range
VID 1 to 4094
Alarm Contact Channels
Relay output with current carrying capacity of 1 A @ 24 VDC

Descargar

No hay ninguna opinión por el momento.