IEC-G102-BP-Pro-H-T
Industrial Intrusion Prevention System (IPS) device with 2 10/100/1000BaseT(X) ports, centralized management via Security Dashboard Console, -40 to 75°C operating temperature
Ficha de datos
- Input/Output Interface: Buttons
- Reset button
- Ethernet Interface: 10/100/1000BaseT(X) Ports (RJ45 connector)
- 2
- Ethernet Interface: Standards
- IEEE 802.3 for 10BaseT, IEEE 802.3ab for 1000BaseT(X), IEEE 802.3u for 100BaseT(X)
- LED Interface: LED Indicators
- PWR1, PWR2, MANAGED, IPS/IDS, USB/F, BYPASS, 10/100/1000M
- DoS and DDoS Protection: Technology
- ICMP Flood, IGMP Flood, UDP Flood, TCP SYN Flood, TCP Port SYN Scan, TCP Port FIN Scan, TCP Port NULL Scan, TCP Port Xmas Scan, UDP Port Scan
- Firewall: IPS Throughput
- Superior a 200 Mbps
- Firewall: Latency
- Inferior a 500 microseconds
- Firewall: Deep Packet Inspection
- Modbus TCP, Modbus UDP, EtherNet/IP, PROFINET-DCP, CIP, SLMP, Omron FINS, Siemens S7 Comm., Siemens S7 Comm. Plus, Additional protocols will be supported through future firmware updates.
- Firewall: Policy Enforcement Rules
- 64 rules
- Firewall: ICS Protocol Filter Profiles
- 32 profiles
- Firewall: Concurrent Connections (TCP)
- 10,000
- Firewall: Automatic Pattern Updates via SDC
- Yes, requires IEC pattern update license
- Firewall: Manual Pattern Updates
- Yes, requires IEC pattern update license
- Management: Supported Interfaces
- Web GUI, Security Dashboard Console (SDC)
- Real-Time Firewall / VPN Event Log: Event Type
- Cybersecurity, Policy enforcement, Protocol Filter, Assets detection, System event
- Real-Time Firewall / VPN Event Log: Media
- Local storage, Syslog server
- Serial Interface: Console Port
- USB Type-C
- Power Parameters: Connection
- Removable terminal block
- Power Parameters: Input Current
- 0.605 A @ 12 VDC, 0.297 A @ 24 VDC, 0.143 A @ 48 VDC
- Physical Characteristics: Housing
- Metal
- Physical Characteristics: Dimensions
- 40 x 70 x 83 mm (1.58 x 2.76 x 3.27 in)
- Physical Characteristics: Weight
- 322 g (0.71 lb)
- Physical Characteristics: Installation
- DIN-rail mounting, Wall mounting (with optional kit)
- Environmental Limits: Operating Temperature
- -40 to 75°C (-40 to 167°F)
- Environmental Limits: Storage Temperature
- -40 to 85°C (-40 to 185°F)
- Environmental Limits: Ambient Relative Humidity
- 5 to 95% (non-condensing)
- Standards and Certifications: EMC
- EN 55032/35
- Standards and Certifications: EMI
- CISPR 32, FCC Part 15B Class A
- Standards and Certifications: EMS
- IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m, IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV, IEC 61000-4-5 Surge: Power: 0.5 kV; Signal: 1 kV, IEC 61000-4-6 CS: 3 V, IEC 61000-4-8 PFMF
- Standards and Certifications: Safety
- UL 60950-1 Ed.2, UL 62368-1
- Standards and Certifications: Hazardous Locations
- UL/cUL Class I Division 2 Groups A/B/C/D
- Standards and Certifications: Railway
- EN 50121-4
- Standards and Certifications: Traffic Control
- NEMA TS2
- Standards and Certifications: Freefall
- IEC 60068-2-32
- Standards and Certifications: Shock
- IEC 60068-2-27
- Standards and Certifications: Vibration
- IEC 60068-2-6
- MTBF: Time
- 1,340,000 hrs
- MTBF: Standards
- Telcordia (Bellcore), GB
- Warranty: Warranty Period
- 5 years
- Warranty: Details
- See www.moxa.com/warranty