UPort 1250I

Conversor USB - Serie hub RS-232/422/485 - 2 portas, com isolamento de 2 kV. 

Para mais informações Contacte-nos

Quantidade

Hub de USB a serie de 2 puertos RS-232/422/485 con aislamiento de 2kV

Ficha informativa

Isolation
2 kV (I models)
Serial Standards
RS-232, RS-422, RS-485
No. of Ports
2
Baudrate
50 bps to 921.6 kbps
Parity
None, Even, Odd, Space, Mark
Data Bits
5, 6, 7, 8
Stop Bits
1, 1.5, 2
Flow Control
None, RTS/CTS, XON/XOFF
RS-485-2w
Data+, Data-, GND
Input Voltage
12 to 48 VDC
Dimensions
77 x 26 x 111 mm (3.03 x 1.02 x 4.37 in)
Peso
Packaged: 680 g (1.5 lb) Product only: 180 g (0.4 lb)
Housing
Metal
Operating Temperature
0 to 55°C (32 to 131°F)
Storage Temperature (package included)
-20 to 75°C (-4 to 167°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
EMC
EN 55032/24
Safety
UL 60950-1
EMI
CISPR 32, FCC Part 15B Class 1
EMS
IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-5 Surge: Power: 1 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF
Green Product
RoHS, CRoHS, WEEE
Time
563,179 hrs
Standards
Telcordia (Bellcore), GB
Warranty Period
5 years
Connector
DB9 male
Input Current
200 mA @ 12 VDC
Speed
12 Mbps, 480 Mbps
USB Connector
USB Type B
USB Standards
USB 2.0
RS-232
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422
Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w
Tx+, Tx-, Rx+, Rx-, GND

No customer reviews for the moment.